Process Technology

Wet Process Heating and Cooling Equipment

DSL Series, Digital Combination Controls

MODEL NUMBER

VOLTS (See Thermal Overload Protection)

MAX. AMPS REPL. RELAY P/N REPL.
RELAY P/N
(LESS TRANS.)
REPL. TRANS. P/N REPL. SENSORS SHIP WGT.
Lbs./(kg)
DSL302 240 30 AH30-1 AH30-2 HD50 2/1 RTD1000 16 (7.5)
DSL304 480 30 AH30-1   HD50 4/1 RTD1000 16 (7.5)
DSL502 240 50 AH50-1 AH50-2 HD50 2/1 RTD1000 17 (8)
DSL504 480 50 AH50-1   HD50 4/1 RTD1000 17 (8)
DSL752 240 75 AH75-1 AH75-2 HD100 2/1 RTD1000 23 (10.5)
DSL754 480 75 AH75-1   HD100 4/1 RTD1000 23 (10.5)
DSL902 240 90 AH90-1 AH90-2 HD100 2/1 RTD1000 25 (11.5)
DSL904 480 90 AH90-1   HD100 4/1 RTD1000 25 (11.5)
DSL1202 240 120 AH120-1 AH120-2 HD100 2/1 RTD1000 27 (12.5)
DSL1204 480 120 AH120-1   HD100 4/1 RTD1000 27 (12.5)
DSL1502 240 150 AH150-1 AH150-2 HD150 2/1 RTD1000 33 (15)
DSL1504 480 150 AH150-1   HD150 4/1 RTD1000 33 (15)
Combination control consists of gasketed plastic enclosure, thermostat, contactor and optional control transformer. To omit step-down transformer, add "LT" to end of model number.
**
Thermal Protection Systems

Product Features and Benefits:

IMPROVES PROCESS CONTROL: Easy to read dual LED displays (.3 inches high). Two set points (heating and cooling). Provides precise control for consistent plating and etch rates in most aqueous processes.

TEMPERATURE SENSOR: Fluoropolymer (FEP) covered 10-foot (3m), 1000-ohm platinum RTD sensor included standard with the control. Provides extended service in corrosive liquids and can be lengthened with ordinary copper hookup wire.

CORROSION RESISTANT ENCLOSURE: NEMA 1, IP23, gasketed plastic enclosure with sealed tactile switches and stainless steel hardware.

CERTIFICATIONS: cUL.

CAPACITIES:

Large switching capacities from 30 to 150 amps for either 240 or 480 volts (other voltages available).
Single pole single-throw switch rated at 3 amps for cooling loads.
Adjustable temperature range from -328°F (-200°C) to 4208°F (2320°C).
+/- .25% full span, single digit accuracy.
20°F (-7°C) to 130°F (54°C) ambient temperature range.
120, 208, 380, 415, 600 and other voltages available.
Single or three phase.

Control transformer required above 240 volts and recommended for 208 and 240 volt service.

SPECIAL FEATURES: Auto tune PID, PID or On/Off control with Auto/Manual operation.

SAFETY FEATURES:

Pre-wired PI terminal blocks.
Non-volatile memory.
Programmable high alarm shutdown.
Sensor short and break protection.
Programmable high setpoint limit.
Security code restricted menu.

OPTIONS AVAILABLE (consult factory):

25-foot (7.6m) and 50-foot (15.2m) sensors.
Pre-wired outlets for plug-in heaters (some sizes).
Ground fault protection (GFP) circuitry.
PII or PIII thermal protection systems.
Integral liquid level control components.
Front panel mounted digital timers.
Three wire 100-ohm RTD sensors.
Type J, K, T, and R thermocouples.
Special sensors. Required for temperatures above 500°F (260°C).
Scalable voltage and current inputs.
4-20 mA or 0-10VDC outputs for process recording.
4-20 mA or 15VDC control outputs.
Voltage, relay, logic/SSR and current outputs.
RS232 or RS485 communication protocol.
CE compliance.
Outdoor enclosures.

DOWNLOAD THE INFORMATION SHEET (including dimensional diagram) IN .PDF FORMAT (approximately 100-150KB).  You will need the Adobe Acrobat program to view the information sheet. If you do not have Adobe Acrobat and would like to download it for free, press the button below.

acrobat.gif (1692 bytes)

[ Home | Search our Site | Industrial Products | Aquaculture Products ]
[
High Purity Products | Product Specials | Company Profile ]
[ Trade Shows | What's New | Employment Opportunities ]
[ Troubleshooting Guide | PDF Files | Contact Us ]